SPECIFICATION
OutputSPEC MODEL NO.VP-0502000VP-0901200VP-1201000VP-1201500VP-1801000VP-2400750
DC VOLTAGE5V9V12V12V18V24V
RATED CURRENT2A1.2A1A1.5A1.0A0.75A
CURRENT RANGE0-2.0A0-1.2A0-1A0-1.5A0-1.0A0-0.75A
RATED POWER10W12W12W18W18W18W
RIPPLE & NOISE(MAX)1%1%1%1%1%1%
VOLTAGE TOLERANCE  ±5%±5%±5%±5%±5%±5%
LINE REGULATION1%1%1%1%1%1%
LOAD REGULATION±5%±5%±5%±5%±5%±5%
SETUP,RISE,HOLD UP TIME300ms, 50ms, 12ms/230VAC          1300ms, 50ms, 12ms/115VAC  at full load
InputVOLTAGE RANGE 100-240V AC
FREQUENCY 50/60HZ
EFFICIENCY  81.5%83.5%83.0%84.0%85.0%85.5%
AC CURRENT0.5A / 115VAC       0.3A / 230VAC
INRUSH CURRENT (max.)COLD START 30A / 115VAC     60A / 230VAC
LEAKAGE CURRENT (max.)0.25mA / 240VAC
ProtectionOVER LOAD110 ~ 200%  rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
ENVIRONMENTWORKING TEMP.0 - +50℃  
WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 - +85℃,5 to 95% RH
TEMP. COEFFICIENT0.03%  /°C(0 ~ 40℃ )
VIBRATION10-500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
   EMC
SAFETY STANDARDSEN-60950-1 , IEC 60950-1 Approval
WITHSTAND VOLTAGEI/P-O/P:4242VDC
ISOLATION RESISTANCEI/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ℃
EMC EMISSIONCompliance to EN55022 class B,  EN61000-3-2,3, FCC part15 class B
EMC IMMUNITYCompliance to EN61000-3-2,3 
OTHERSMTBF780Khrs min.      MIL-HDBK-217F (25 )
DIMENSION75.0*28.0*39.0mm
PACKING90g/pc;  100pcs/carton
CONNECTORPLUGSee page 2  ; Other type available by customer requested
CABLESee page 2  ; Other type available by customer requested
NOTE  1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 
  2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 
  3.Tolerance: includes set up tolerance, line regulation, load regulation.        
  4.Line regulation is measured from low line to high line at rated load.       
  5.Load regulation is measured from 10% to 100% rated load.       
  6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification provided by the IC manufacturer.