18W/24W/30W Wall Mount Series

Products > Power Adapter > 18W/24W/30W Wall Mount Series

18W/24W/30W Wall Mount Series

Min.Order Quantity: 3K PCS
Port: ShenZhen
Payment Terms: T/T,Western Union,PayPal
Porudct time: 10 to 15 working days or depending on the order
Package: Carton
2 years warranty
shared:
SPECIFICATION
OutputSPEC MODEL NO.VP-0504000VP-0902000VP-1201500VP-1202000VP-150200VP-1801500VP-2401500
DC VOLTAGE5V9V12V12V15V18V24V
RATED CURRENT4A2A1.5A2A2A1.5A1.25A
CURRENT RANGE0-4.0A0-2.0A0-1.5A0-2A0-2A0-1.5A0-1.25A
RATED POWER20W18W18W24W30W27W30W
RIPPLE & NOISE(MAX)1%1%1%1%1%1%1%
VOLTAGE TOLERANCE  ±5%±5%±5%±5%±5%±5%±5%
LINE REGULATION1%1%1%1%1%1%1%
LOAD REGULATION±5%±5%±5%±5%±5%±5%±5%
SETUP,RISE,HOLD UP TIME500ms, 30ms / 230VAC          1000ms, 30ms / 115VAC  at full load
InputVOLTAGE RANGE 100-240V AC
FREQUENCY 50/60HZ
EFFICIENCY  81.5%83.0%83.0%84.0%85.0%85.0%85.5%
AC CURRENT0.9A / 115VAC       0.45A / 230VAC
INRUSH CURRENT (max.)30A / 115VAC     55A / 230VAC
LEAKAGE CURRENT (max.)Touch current < 50μA/264VAC
ProtectionOVER LOAD105 ~ 170%  rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE5.25 ~ 7.5V7.88-10.5V9.45-13V12.6-17.2V15.75-20.25V18.9-25.2V25.2-32.4V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENTWORKING TEMP.0 - +50℃  
WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 - +85℃,5 to 95% RH
TEMP. COEFFICIENT 0.03%  /°C (0 ~ 40℃ )
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
     EMC
SAFETY STANDARDSUL 60950-1 CSA-60950-1 IEC 60950-1  EN 60950-1 EN61347 
WITHSTAND VOLTAGEI/P-O/P:KVDC
ISOLATION RESISTANCEI/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ℃
EMC STANDARDSCompliance to EN55022 class B,  EN61000-3-2,3,  EN55024
Compliance to FCC part15 class B
OTHERSMTBF650Khrs min.      MIL-HDBK-217F (25 °C)
DIMENSION(L*W*H)86x 48 x 31 mm
PACKING155g  60pcs/carton
CONNECTORPLUGSee page 2  ; Other type available by customer requested
CABLESee page 2  ; Other type available by customer requested
NOTE

1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 
2.DC voltage:The output voltage set at point measure by plug terminal&50% load
3.Ripple& noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor. 
4.Tolerance: includes set up tolerance, line regulation, load regulation.        
5.Line regulation is measured from low line to high line at rated load.       
6.Length of set up time is measured at first cold start.Turning ON/OFF the power supply may lead to increase of the set up time
7.Derating may be needed under low input voltage.Please check the derating curve for more details.      
8.The power supply is considered as an independent unit,but the final equipment still need to re-confirm that the whole system complies with the EMC directives.For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

Name
Phone
Email
Corporate name
Address
Leaving Message*
 
Verification code
Submit