SPECIFICATION
OutputSPEC MODEL NO.VP-0500600VP-0501000VP-0501200VP-1200500VP-1200800VP-1201000
DC VOLTAGE5V5V5V12V12V12V
RATED CURRENT600mA1.0A1.2A0.5A0.8A1.0A
CURRENT RANGE0-0.6A0-1.0A0-1.2A0-0.5A0-0.8A0-1.0A
RATED POWER3W5W6W6W10W12W
RIPPLE & NOISE(MAX)1%1%1%1%1%1%
VOLTAGE TOLERANCE  ±5%±5%±5%±5%±5%±5%
LINE REGULATION1%1%1%1%1%1%
LOAD REGULATION±5%±5%±5%±5%±5%±5%
SETUP,RISE,HOLD UP TIME300ms, 50ms, 12ms/230VAC          1300ms, 50ms, 12ms/115VAC  at full load
InputVOLTAGE RANGE 100-240V AC
FREQUENCY 50/60HZ
EFFICIENCY  83.0%83.5%83.0%84.0%85.0%85.5%
AC CURRENT0.5A / 115VAC       0.3A / 230VAC
INRUSH CURRENT (max.)COLD START 30A / 115VAC     60A / 230VAC
LEAKAGE CURRENT (max.)0.25mA / 240VAC
ProtectionOVER LOAD110 ~ 200%  rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
ENVIRONMENTWORKING TEMP.0 - +50℃  
WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 - +85℃,5 to 95% RH
TEMP. COEFFICIENT0.03%  /°C(0 ~ 40℃ )
VIBRATION10-500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY &
   EMC
SAFETY STANDARDSEN-60950-1 , IEC 60950-1 Approval
WITHSTAND VOLTAGEI/P-O/P:4242VDC
ISOLATION RESISTANCEI/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ℃
EMC EMISSIONCompliance to EN55022 class B,  EN61000-3-2,3, FCC part15 class B
EMC IMMUNITYCompliance to EN61000-3-2,3 
OTHERSMTBF780Khrs min.      MIL-HDBK-217F (25 )
DIMENSION46.0*36.0*23.0mm
PACKING60g/pc;  200pcs/carton
CONNECTORPLUG1xUSB port
CABLESee page 2  ; Other type available by customer requested
NOTE1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 
2.DC voltage:The output voltage set at point measure by plug terminal&50% load
3.Ripple& noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor. 
4.Tolerance: includes set up tolerance, line regulation, load regulation.        
5.Line regulation is measured from low line to high line at rated load.       
6.Length of set up time is measured at first cold start.Turning ON/OFF the power supply may lead to increase of the set up time
7.Derating may be needed under low input voltage.Please check the derating curve for more details.      
8.The power supply is considered as an independent unit,but the final equipment still need to re-confirm that the whole system complies with the EMC directives.For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”