SPECIFICATION | |||||||
Output | SPEC MODEL NO. | VP-0500600 | VP-0501000 | VP-0501200 | VP-1200500 | VP-1200800 | VP-1201000 |
DC VOLTAGE | 5V | 5V | 5V | 12V | 12V | 12V | |
RATED CURRENT | 600mA | 1.0A | 1.2A | 0.5A | 0.8A | 1.0A | |
CURRENT RANGE | 0-0.6A | 0-1.0A | 0-1.2A | 0-0.5A | 0-0.8A | 0-1.0A | |
RATED POWER | 3W | 5W | 6W | 6W | 10W | 12W | |
RIPPLE & NOISE(MAX) | 1% | 1% | 1% | 1% | 1% | 1% | |
VOLTAGE TOLERANCE | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
LINE REGULATION | 1% | 1% | 1% | 1% | 1% | 1% | |
LOAD REGULATION | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
SETUP,RISE,HOLD UP TIME | 300ms, 50ms, 12ms/230VAC 1300ms, 50ms, 12ms/115VAC at full load | ||||||
Input | VOLTAGE RANGE | 100-240V AC | |||||
FREQUENCY | 50/60HZ | ||||||
EFFICIENCY | 83.0% | 83.5% | 83.0% | 84.0% | 85.0% | 85.5% | |
AC CURRENT | 0.5A / 115VAC 0.3A / 230VAC | ||||||
INRUSH CURRENT (max.) | COLD START 30A / 115VAC 60A / 230VAC | ||||||
LEAKAGE CURRENT (max.) | 0.25mA / 240VAC | ||||||
Protection | OVER LOAD | 110 ~ 200% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 110 ~ 140% rated output voltage | ||||||
Protection type : Clamp by zener diode, output short | |||||||
ENVIRONMENT | WORKING TEMP. | 0 - +50℃ | |||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -20 - +85℃,5 to 95% RH | ||||||
TEMP. COEFFICIENT | 0.03% /°C(0 ~ 40℃ ) | ||||||
VIBRATION | 10-500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC | SAFETY STANDARDS | EN-60950-1 , IEC 60950-1 Approval | |||||
WITHSTAND VOLTAGE | I/P-O/P:4242VDC | ||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ℃ | ||||||
EMC EMISSION | Compliance to EN55022 class B, EN61000-3-2,3, FCC part15 class B | ||||||
EMC IMMUNITY | Compliance to EN61000-3-2,3 | ||||||
OTHERS | MTBF | 780Khrs min. MIL-HDBK-217F (25 ) | |||||
DIMENSION | 46.0*36.0*23.0mm | ||||||
PACKING | 60g/pc; 200pcs/carton | ||||||
CONNECTOR | PLUG | 1xUSB port | |||||
CABLE | See page 2 ; Other type available by customer requested | ||||||
NOTE | 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2.DC voltage:The output voltage set at point measure by plug terminal&50% load 3.Ripple& noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Length of set up time is measured at first cold start.Turning ON/OFF the power supply may lead to increase of the set up time 7.Derating may be needed under low input voltage.Please check the derating curve for more details. 8.The power supply is considered as an independent unit,but the final equipment still need to re-confirm that the whole system complies with the EMC directives.For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” |