SPECIFICATION | ||||||||
Output | SPEC MODEL NO. | VP-0503000 C | ||||||
DC VOLTAGE | 5V | 9V | 12V | 5V | 9V | 12V | 5V | |
RATED CURRENT | 3000mA | 2200mA | 1670mA | A | A | A | A | |
CURRENT RANGE | 0-3A | 0-2.2A | 0-1.67A | A | A | 0-1.1A | A | |
RATED POWER | 15W | 6W | 6W | W | W | 6W | W | |
RIPPLE & NOISE(MAX) | 1% | 1% | 1% | 1% | 1% | 1% | 1% | |
VOLTAGE TOLERANCE | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
LINE REGULATION | 1% | 1% | 1% | 1% | 1% | 1% | 1% | |
LOAD REGULATION | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
SETUP,RISE,HOLD UP TIME | 300ms, 50ms, 12ms/230VAC 1300ms, 50ms, 12ms/115VAC at full load | |||||||
Input | VOLTAGE RANGE | 100-240V AC | ||||||
FREQUENCY | 50/60HZ | |||||||
EFFICIENCY | 91.5% | 92.0% | 92.5% | % | % | % | % | |
AC CURRENT | 0.5A / 115VAC 0.3A / 230VAC | |||||||
INRUSH CURRENT (max.) | COLD START 30A / 115VAC 60A / 230VAC | |||||||
LEAKAGE CURRENT (max.) | 0.25mA / 240VAC | |||||||
Protection | OVER LOAD | 110 ~ 200% rated output power | ||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 110 ~ 140% rated output voltage | |||||||
Protection type : Clamp by zener diode, output short | ||||||||
ENVIRONMENT | WORKING TEMP. | 0 - +50℃ | ||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -20 - +85℃,5 to 95% RH | |||||||
TEMP. COEFFICIENT | 0.03% /°C(0 ~ 40℃ ) | |||||||
VIBRATION | 10-500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||
SAFETY & EMC | SAFETY STANDARDS | EN-62368-1 , IEC 62368-1 Approval | ||||||
WITHSTAND VOLTAGE | I/P-O/P:4242VDC | |||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ℃ | |||||||
EMC EMISSION | Compliance to EN55022 class B, EN61000-3-2,3, FCC part15 class B | |||||||
EMC IMMUNITY | Compliance to EN61000-3-2,3 | |||||||
OTHERS | MTBF | 780Khrs min. MIL-HDBK-217F (25 ) | ||||||
DIMENSION | 36.0*30.0*67.0mm | |||||||
PACKING | 60g/pc; 200pcs/carton | |||||||
CONNECTOR | PLUG | 1xUSB-C port | ||||||
CABLE | See page 2 ; Other type available by customer requested | |||||||
NOTE | 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Tolerance: includes set up tolerance, line regulation, load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 10% to 100% rated load. 6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification provided by the IC manufacturer. |