SPECIFICATION | ||||||||
Output | SPEC MODEL NO. | VP-0504000 | VP-0754000 | VP-0904000 | VP-1203000 | VP-1502400 | VP-1802000 | VP-2401500 |
DC VOLTAGE | 5V | 7.5V | 9V | 12V | 15V | 18V | 24V | |
RATED CURRENT | 4A | 4A | 4A | 3A | 2.4A | 2A | 1.5A | |
CURRENT RANGE | 0-4A | 0-4A | 0-4A | 0-3A | 0-2.4A | 0-2A | 0-1.5A | |
RATED POWER | 20W | 30W | 36W | 36W | 36W | 36W | 36W | |
RIPPLE & NOISE(MAX) | 1% | 1% | 1% | 1% | 1% | 1% | 1% | |
VOLTAGE TOLERANCE | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
LINE REGULATION | 1% | 1% | 1% | 1% | 1% | 1% | 1% | |
LOAD REGULATION | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | ±5% | |
SETUP,RISE,HOLD UP TIME | 500ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load | |||||||
Input | VOLTAGE RANGE | 100-240V AC | ||||||
FREQUENCY | 50/60HZ | |||||||
EFFICIENCY | 82.0% | 82.0% | 82.0% | 86.0% | 87.0% | 87.0% | 88.0% | |
AC CURRENT | 0.9A / 115VAC 0.45A / 230VAC | |||||||
INRUSH CURRENT (max.) | 30A / 115VAC 55A / 230VAC | |||||||
LEAKAGE CURRENT (max.) | Touch current < 50μA/264VAC | |||||||
Protection | OVER LOAD | 105 ~ 170% rated output power | ||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 5.25 ~ 7.5V | 7.88-10.5V | 9.45-13V | 12.6-17.2V | 15.75-20.25V | 18.9-25.2V | 25.2-32.4V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT | WORKING TEMP. | 0 - +50℃ | ||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -20 - +85℃,5 to 95% RH | |||||||
TEMP. COEFFICIENT | 0.03% /°C (0 ~ 40℃ ) | |||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||
SAFETY & EMC | SAFETY STANDARDS | UL 60950-1 CSA-60950-1 IEC 60950-1 EN 60950-1 EN61347 | ||||||
WITHSTAND VOLTAGE | I/P-O/P:KVDC | |||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH ℃ | |||||||
EMC STANDARDS | Compliance to EN55022 class B, EN61000-3-2,3, EN55024 | |||||||
Compliance to FCC part15 class B | ||||||||
OTHERS | MTBF | 650Khrs min. MIL-HDBK-217F (25 °C) | ||||||
DIMENSION(L*W*H) | 98 x 47 x 32 mm | |||||||
PACKING | 160g 40pcs/carton | |||||||
CONNECTOR | PLUG | See page 2 ; Other type available by customer requested | ||||||
CABLE | See page 2 ; Other type available by customer requested | |||||||
NOTE | 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. complies with the EMC directives.For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” |